When was this facility last ordered closed?
This facility has no closure records in our database.
Detailed inspection and closure history
This facility has no closure records in our database.
The most recent inspection was on 04/11/2025 CONDITIONAL .
Field | Value |
---|---|
inspection_id | 14335 |
inspection_date | 2025-04-11 |
standardized_result | conditional_pass |
original_result | Pass w/ Conditions |
Violation 1 | |
violation_code | 33. |
violation_description | PROPER COOLING METHODS USED; ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL |
violation_comment | OBSERVED TWO (2) DOOR STANDING COOLER PRESENT AND UNPLUGGED IN REAR PREP AREA AT TIME OF INSPECTION. UNIT WAS NOT IN USE, ON OR RUNNING, AND MANAGER STATED THAT UNIT WAS DELIVERED WITHIN THE PAST DAY, AND THEY WERE INSTRUCTED TO WAIT OVER 24 HRS AFTER DELIVERY BEFORE TURNING ON. STANDING TWO (2) DOOR COOLER TAGGED AND HELD FOR INSPECTION AT THIS TIME. INSTRUCTED NOT TO USE UNTIL EQUIPMENT IS ABLE TO MAINTAIN TEMPERATURES OF AT LEAST 41F AND REINSPECTED BY CDPH. PRIORITY VIOLATION, 7-38-005. |
Violation 2 | |
violation_code | 47. |
violation_description | FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED |
violation_comment | OBSERVED CHEST FREEZER STORED ON CARDBOARD AND STYROFOAM ON ELEVATED SHELF IN REAR PREP AREA AT TIME OF INSPECTION. INSTRUCTED MANAGER TO REMOVE AND ENSURE ALL SURFACES ARE SMOOTH AND EASILY CLEANABLE. |
Violation 3 | |
violation_code | 51. |
violation_description | PLUMBING INSTALLED; PROPER BACKFLOW DEVICES |
violation_comment | OBSERVED HOT WATER DISPENSER PLUGGED IN AND ATTACHED TO PLUMBING AT FRONT PREP AREA WITH NO BACKFLOW PREVENTION DEVICE PRESENT IN WATER LINE. INSTRUCTED MANAGER TO PROVIDE BACKFLOW PREVENTION DEVICE. |
Violation 4 | |
violation_code | 51. |
violation_description | PLUMBING INSTALLED; PROPER BACKFLOW DEVICES |
violation_comment | OBSERVED LEAK FROM DRAIN IN HAND SINK LOCATED IMMEDIATELY NEXT TO 3 COMPARTMENT SINK. WATER LEAKS HEAVILY ONTO FLOOR FROM DRAIN PIPE WHEN WATER IS RUN. OBSERVED HAND SINK IN REAR PREP AREA IN THE SOUTHERN END OF PREP AREA TO BE SLOW DRAINING WHEN USED. BOTH SINKS ARE STILL FUNCTIONAL. INSTRUCTED TO SERVICE HAND SINK DRAINS AND MAINTAIN IN GOOD REPAIR. |
Violation 5 | |
violation_code | 53. |
violation_description | TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED |
violation_comment | OBSERVED DOOR TO BATHROOM TO HAVE SELF CLOSING MECHANISM NOT ATTACHED AT TIME OF INSPECTION. INSTRUCTED MANAGER TO RE-ATTACH/PROVIDE A SELF CLOSING BATHROOM DOOR. |
Violation 6 | |
violation_code | 55. |
violation_description | PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN |
violation_comment | OBSERVED MISSING BASEBOARD ALONG THE FLOOR AND WALL JUNCTURES ON ALL EAST WALL BEHIND 3 COMPARTMENT SINK AND HAND SINKS IN REAR PREP AREA. INSTRUCTED MANAGER TO PROVIDE BASEBOARD IN ALL FLOOR/WALL JUNCTURES THROUGHOUT FACILITY, ESPECIALLY IN AREAS THAT ARE EXPOSED TO MOISTURE. |
Violation 7 | |
violation_code | 55. |
violation_description | PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN |
violation_comment | NOTED GAP BETWEEN FLOOR SINK AND WALLS AT BOTH UTILITY SINK IN REAR PREP AREA. INSTRUCTED TO ADDRESS CLEANABILITY BY FILLING GAP. |
Violation 8 | |
violation_code | 3. |
violation_description | MANAGEMENT, FOOD EMPLOYEE AND CONDITIONAL EMPLOYEE; KNOWLEDGE, RESPONSIBILITIES AND REPORTING |
violation_comment | OBSERVED NO WRITTEN EMPLOYEE HEALTH POLICY ON THE PREMISES. INSTRUCTED TO PROVIDE A SIGNED EMPLOYEE HEALTH POLICY FOR EACH EMPLOYEE AND MAINTAIN AS REQUIRED. PRIORITY FOUNDATION VIOLATION, 7-38-010. |
Data provided by: Chicago Department of Public Health's Food Protection Program
CleanKitchens.org presents this information as a public service. While we strive for accuracy, please refer to the original data source for official records.
Stay up-to-date with the latest restaurant Closures, Inspections, and Violations in CHICAGO.