Section 5-203.12.

6-302.11 Toilet Tissue, Availability.

A supply of toilet tissue shall be available at each toilet. Pf

6-303.11 Lighting -- Intensity.

The light intensity shall be:

(A) At least 108 lux (10 foot candles) at a distance of 75 cm

(30 inches) above the floor, in walk-in refrigeration units and

dry FOOD storage areas and in other areas and rooms during

periods of cleaning;

199

(B) At least 215 lux (20 foot candles):

(1) At a surface where FOOD is provided for CONSUMER

self-service such as buffets and salad bars or where fresh

produce or PACKAGED FOODS are sold or offered for

consumption,

(2) Inside EQUIPMENT such as reach-in and undercounter refrigerators; and

(3) At a distance of 75 cm (30 inches) above the floor in

areas used for handwashing, WAREWASHING, and

EQUIPMENT and UTENSIL storage, and in toilet rooms;

and

(C) At least 540 lux (50 foot candles) at a surface where a

FOOD EMPLOYEE is working with FOOD or working with

UTENSILS or EQUIPMENT such as knives, slicers, grinders, or

saws where EMPLOYEE safety is a factor.

6-304.11 Ventilation -- Mechanical.

To keep rooms free of excessive heat, steam, condensation, vapors,

obnoxious odors, smoke, and fumes, mechanical ventilation of

sufficient capacity shall be provided as required by LAW.

6-305.11 Dressing Areas and Lockers -- Designation.

(A) Dressing rooms or dressing areas shall be designated if

EMPLOYEES routinely change their clothes in the establishment.