202.13, a dual check valve with an intermediate vent precede
screen of not less than 100 mesh to 25.4 mm (100 mesh to 1 inch) shall
be installed upstream from a carbonating device and downstream from
any copper in the water supply line.P
(B) A dual check valve attached to the carbonator need not be of the
vented type if an air gap or vented backflow prevention device has been
otherwise provided as specified under Paragraph (A) of this section.
178
5-204.11 Handwashing Sinks.
A HANDWASHING SINK shall be located:
(A) To allow convenient use by EMPLOYEES in all FOOD
preparation, FOOD dispensing, and WAREWASHING areas; Pf and
(B) In, or immediately adjacent to, toilet rooms.Pf
(C) RETAIL FOOD ESTABLISHMENTS shall install handwashing sinks in
locations as specified in this section. Pf
5-204.12 Backflow Prevention Device, Location.
A backflow prevention device shall be located so that it may be serviced and
maintained.
5-204.13 Conditioning Device, Location.
A water filter, screen, and other water conditioning device installed on water
lines shall be located to facilitate disassembly for periodic servicing and
cleaning.
5-205.11 Using a Handwashing Sink.
(A) A HANDWASHING SINK shall be maintained so that it is accessible at
all times for EMPLOYEE use. Pf
(B) A HANDWASHING SINK may not be used for purposes other than
handwashing.Pf
(C) An automatic handwashing facility shall be used in accordance with
179
manufacturer’s instructions.Pf
5-205.12 Prohibiting a Cross Connection.